Personnel

One technician

 

 

 

Safety

NOTICE

notice

Refer to Safety Instructions before performing any operation on the RMI System.

 

 

 

Tools and Equipment

  • 4mm Allen key
  • Cutter
  • Phillips screwdriver

 

 

 

Preparations

    1. Remove the crate's top and side covers.
    2. Remove the protective film from the RMI System.
    3. Using a cutter, remove five cable ties securing the corrugated tube.
    4. Using a Phillips screwdriver, remove the four screws, washers, and clamps securing the main unit to the crate.
    5. Using a Phillips screwdriver, remove four screws, washers, and clamps securing the control unit to the crate.
    6. WARNING

      warning

      Lifting the RMI units requires four people.

      Failure to comply may result in a serious injury.

    7. Lift the main unit and control unit from the pallet and position at the designated installation location.
      System Installation - Preparations

       

       

      Procedure – Part 1

        1. Remove the LED tower light from its packaging.
        2. Connect the LED tower harness to the control unit.
        3. Insert the LED tower to the LED tower mount.
        4. If the hopper was packaged separately, remove it from its packaging.
        5. Using a 4mm Allen key, install four screws securing the hopper to the main unit.
        6. Using a key, open the control unit's front door.
        7. Remove the moisture absorbing bag from the control unit.
          System Installation - Procedure Part 1

           

           

          Procedure – Part 2

            1. Open the transparent camera door on the front side of the system.
            2. Remove the lens covers from all cameras.
            3. Open the transparent camera door on the back side of the system.
            4. Remove the lens covers from all cameras.
            5. WARNING

              warning

              Only a certified electrician should connect the control unit.

              Failure to comply may result in injury or damage to equipment.

            6. Connect the control unit to mains power.
            7. NOTICE

              notice

              A 100kVA UPS can be installed inside the control unit.

            8. Connect the control unit to a UPS.
            9. Connect the control unit's Ethernet cable to an RJ-45 terminal.
            10. NOTICE

              notice

              If required, run a digital I/O cable through the corrugated tube to the electric enclosure on the control stand.

            11. Remove the air tube from behind the touchscreen's door.
            12. Connect air supply to the air treatment port on the main unit.
            13. Power on the system.
              System Installation - Procedure Part 2